E-mail


RapidTAG RFID On-Metal Extreme2
View Full-Size Image


RapidTAG RFID On-Metal Extreme2

Price per Unit (piece): Call for Pricing

Ask a question about this product

RapidTAG Mount-On-Metal Extreme2 is a High Temperature & Chemical Resistance RFID Tag with just 1 inch long, smaller than any other UHF Gen2 RFID metal tags with 3.0mm thickness. Tag read range performance between 50cm ~ 150cm depending on reader used.

RapidTAG have already passed various kinds temperature/humidity tests in US, Japan, UK and Germany.

  Test Characteristic
 Result
 1 Humidity chamber test (85/95% RH Test) Pass (May 2009)
 
  • 168 hours’ chamber test at 85C degree/ 95% relative humidity
  • Passes if difference between prechamber and post chamber tag’s resonant center frequency is below 5MHz
 
 2 High temperature test (200°C Test) Pass (February 2009)
 
  • 6 hours’ chamber test at 200C degree
  • Passes if difference between pre-chamber and post chamber tag’s resonant center frequency is below 5MHz
 
 3 Thermal cycling test (-45°C⇔85°C Test) Pass (May 2009)
 
  • Total 500 cycles with each cycle 90 minutes from 45°C degree to 85°C degree
  • Passes if difference between prechamber and post chamber tag’s resonant center frequency is below 5MHz
 
 4 High temperature oil test (200°C Oil Test) Pass (February 2009)
 
  • Soaked 6 hours at 200C degree boiling oil
  • Passes if difference between prechamber and post chamber tag’s resonant center frequency is below 5MHz
 
 5 Ingression IP68 Pass (April 2009)
 
  • Soaked 1.5 meter water depth for 24 hours
  • Passes if difference between pre-chamber and post-chamber  tag’s resonant center frequency is below 5MHz
 
 6 Vibration IEC60068-2-6/64 Pass (July 2009)
 
  • Vibrates tags with various frequency and gravity
  • Passes if difference between pre-chamber and post-chamber  tag’s resonant center frequency is below 5MHz
 
 7 Iron ball free fall (1 kg) Pass (December 2009)
 
  • 1 Kg iron ball free fall from 1.5 meters’ height on tags for 50 times at different angles
  • Passes if difference between pre-chamber and post-chamber tag’s resonant center frequency is below 5MHz

 
8
 Drop&  topple IEC60068-2-31
 Pass (July 2009)
 
  • Drop tags from 1.0 meters’ height at different angles
  • Passes if difference between pre-chamber and post-chamber  tag’s resonant center frequency is below 5MHz
 

RapidTAG have passed various chemical tests as below in several countriesRTM2I-1-Test









   Home arrow Products arrow RFID Solutions arrow RFID For IT Asset Management arrow RapidTAG RFID On-Metal Extreme2
Copyright © 2008 PT. RFID INDONESIA.